MD Global Health

Free FedEx Ground shipping on every U.S. order · Authorized Charder distributor · Questions? Contact us
Clinical dynamometry

Handgrip Dynamometry in Clinical Practice: A Step-by-Step Protocol with the Charder MG4800

Most clinicians know what a handgrip test is. Fewer know exactly how to perform it reproducibly. Here is the complete protocol, why it matters, and how the Charder MG4800 fits it into a daily workflow.

Handgrip Dynamometry in Clinical Practice: A Step-by-Step Protocol with the Charder MG4800
On this page
  1. Why grip strength is no longer optional
  2. The protocol, step by step
  3. Applying the protocol with the Charder MG4800

Clinical dynamometry

Most clinicians know what a handgrip test is. Fewer know exactly how to perform it reproducibly. Here is the complete protocol, why it matters, and how the Charder MG4800 fits it into a daily workflow.

MD Global Health · For healthcare professionals · 6 min read

Key points
  • Muscle strength is now a core criterion in sarcopenia consensus definitions, and the standard way to measure it is a hand dynamometer.
  • Patients with diabetes or chronic kidney disease deserve closer attention even when their grip strength is above the cut-off.
  • Reproducibility depends almost entirely on a standardized posture.

Why grip strength is no longer optional

Both major consensus groups place strength at the center of muscle assessment. EWGSOP2 uses low grip strength as the first indicator of probable sarcopenia,1 and the AWGS 2025 update defines sarcopenia by low muscle mass plus low muscle strength, extending attention to adults from age 50.2

ReferenceMenWomen
EWGSOP2 (adults)< 27 kg< 16 kg
AWGS 2025, age 50–64< 34.0 kg< 20.0 kg
AWGS 2025, age ≥ 65< 28.0 kg< 18.0 kg

Table 1. Grip-strength cut-offs reported by EWGSOP2 and AWGS 2025. Choose the reference that fits your population and institutional protocol.

For metabolic practice there is an additional point: studies in type 2 diabetes associate low grip strength with insulin resistance and, in older patients, with diabetic foot disease.3 In patients with diabetes or chronic kidney disease, a result just above the cut-off is not a reason to stop monitoring.

The protocol, step by step

The American Society of Hand Therapists (ASHT) positioning protocol is the most widely used and has been confirmed in multiple reliability studies:4

  1. Patient seated, back supported, hips and knees at about 90°.
  2. Shoulder adducted and in neutral rotation, elbow flexed at 90°, forearm in neutral, wrist between 0° and 15° of ulnar deviation.
  3. The arm should not rest on the examiner, the chair or the table. The dynamometer is held vertically, in line with the forearm.

Taking the measurement: perform three attempts per hand, alternating hands with a short rest between attempts to avoid fatigue. Record the maximum value (some protocols use the mean of three attempts, depending on the purpose of the assessment). Use the same protocol at every visit.

What if the patient cannot sit unsupported? This is common after bariatric surgery or with reduced mobility. Supine testing with the elbow flexed has been shown to give reproducible results and is a clinically valid alternative when the standard position is not possible. Document the position used.

Applying the protocol with the Charder MG4800

The MG4800 uses compressible springs. Unlike fixed-grip dynamometers, the compression pattern more closely resembles a natural grip, which makes it well suited both to assessment and to rehabilitation follow-up.

Interchangeable springs, one device

Interchangeable springs of different resistance let you match the device to the patient, from advanced sarcopenia to normal strength, without a second instrument.

Three measurement modes

ModeWhat it measuresWhen to use it
MaxMaximum grip forceStandard assessment, compared against cut-offs
Average (AVG)Average force of the right and left handsComparing both hands and tracking overall strength
CountRepetitions that reach a target forceRehabilitation exercises and strengthening programs

Table 2. MG4800 measurement modes.

Charder Connect: paperless follow-up

The MG4800 connects by Bluetooth to the Charder Connect app for iOS and Android. After each measurement, press Power/Zero to send the result, select right or left hand, and save. Results are organized under each patient’s profile, so you see a trend of grip strength over time, not just a single number, and you can export the data to CSV for your records.

In short: grip strength is a core criterion of muscle health. With a standardized posture and the MG4800 synced to Charder Connect, measuring and tracking it takes less than a minute per patient.

Bring handgrip dynamometry to your practice

Free U.S. shipping, 30-day returns and technical support from an authorized Charder distributor.

See the MG4800Ask a question
References
  1. Cruz-Jentoft AJ, et al. Sarcopenia: revised European consensus on definition and diagnosis. Age and Ageing, 2019.
  2. Chen L-K, et al. A focus shift from sarcopenia to muscle health in the AWGS 2025 Consensus Update. Nature Aging, 2025. doi:10.1038/s43587-025-01004-y.
  3. Studies on grip strength, insulin resistance and diabetic foot disease in type 2 diabetes (Journal of the Endocrine Society, 2024; Turkish Journal of Medical Sciences, 2022).
  4. American Society of Hand Therapists positioning recommendations (1981) and subsequent reliability studies.
  5. Charder Medical. Technical documentation, MG4800 dynamometer and Charder Connect app.

This article is informational for healthcare professionals and does not replace individual clinical judgment. Diagnostic and treatment decisions should be based on a comprehensive evaluation of each patient.

Continue reading

All articles
For clinics & health systems

Bring objective measurement to your practice

Charder body composition analyzers, medical scales, stadiometers and dynamometers — FDA registered, free U.S. shipping and a 12-month warranty.

Join Waitlist We will inform you when the product arrives in stock. Please leave your valid email address below.