Core Muscle Estimation by Bioimpedance: What the Evidence Says

Deep trunk muscles are traditionally measured with CT or MRI. Here is how Charder estimates them by bioimpedance, what data the method was built on, and how to read the results with clinical judgment.

Core Muscle Estimation by Bioimpedance: What the Evidence Says
On this page
  1. Which muscles are we talking about?
  2. How the core is measured in research
  3. How Charder estimates it
  4. Why core muscle matters
  5. Reading the results
  6. Availability

Body composition · Core muscle

Deep trunk muscles are traditionally measured with CT or MRI. Here is how Charder estimates them by bioimpedance, what data the method was built on, and how to read the results with clinical judgment.

MD Global Health · Technical article for healthcare professionals · 8 min read

Key points
  • Charder’s core model was developed against lumbar CT in 286 adults, with coefficients of determination between 0.91 and 0.93 depending on the muscle.
  • Independent literature links paraspinal muscle size with chronic low back pain; the evidence is solid for the multifidus and mixed for other muscles.
  • The result is a useful estimate for follow-up and training guidance, not a substitute for imaging or a diagnostic tool.

A strong core is not the same as visible abs. The psoas, erector spinae, quadratus lumborum and abdominal wall stabilize the trunk and transfer force between the limbs. They are deep, hard to assess without imaging, which is why it is worth understanding what a bioimpedance estimate can and cannot tell us.

Which muscles are we talking about?

  • Psoas major: the main hip flexor and the only muscle connecting the lumbar spine to the lower limbs.
  • Erector spinae: keeps the spine upright and controls trunk flexion, extension and rotation.
  • Quadratus lumborum: provides lateral stability to the pelvis and lumbar spine.
  • Abdominal muscles: rectus, transversus and obliques, which stabilize the spine and act as antagonists of the erector.

How the core is measured in research

Because these muscles are deep, they cannot be assessed by palpation or simple anthropometry. In research, the standard is the cross-sectional area (cm²) on a lumbar CT or MRI slice. A single abdominal slice reflects total-body skeletal muscle well,1 which is why lumbar muscle area is used in oncology, surgery and geriatrics as a marker of muscle reserve. The practical problem: CT means radiation, cost and limited access, and it is not reasonable to repeat it to follow a training program.

How Charder estimates it

Charder developed a patented method (Taiwan, Japan and the U.S.) that estimates core cross-sectional area from standing 8-electrode bioimpedance.2 The model combines the impedance index (height² divided by impedance), age and sex in a regression equation built against CT-measured muscle area.

ItemDevelopment study
Sample286 adults aged 18–77 (146 women, 140 men), BMI 16–40 kg/m²
Reference64-slice CT; muscle area at the L3–L4 level
Total corer² = 0.910 · SEE = 13.42 cm²
Psoas majorr² = 0.919 · SEE = 3.31 cm²
Quadratus lumborumr² = 0.920 · SEE = 5.07 cm²
Erector spinaer² = 0.934 · SEE = 13.07 cm²
AbdominalsTotal core minus the other three groups

Table 1. Development of Charder’s core model against CT. Source: U.S. patent 12,419,532 B2 (Charder Electronic).

An r² of 0.91 means the model explains about 91% of the variation in core muscle area seen on CT, a solid result for an indirect estimate.

Critical reading. These figures come from patent documentation, not a peer-reviewed paper, and describe the group in which the equation was built; no independent validation is reported. The same research group published a preliminary PLOS ONE study of the psoas in 92 older adults with cross-validation (r = 0.846 versus CT, limits of agreement about ±4.5 cm²), and the authors cautioned that the method cannot yet replace CT or MRI clinically.3

That does not make it less useful. Bioimpedance is fast, radiation-free and can be repeated as often as needed, which makes it practical for routine follow-up and for spotting imbalances. Imaging remains the choice when a critical decision depends on an exact value. Independent work supports the concept: a two-center study of 211 colorectal cancer patients developed a bioimpedance equation for CT muscle area with a correlation of 0.93.4

Why core muscle matters

Low back pain. Paraspinal muscles tend to be smaller in chronic low back pain;5 the association is consistent for the multifidus but mixed for the erector spinae, psoas and quadratus lumborum.6 Larger paraspinal area has been linked to less low-back disability, though not lower pain intensity.7

Sports injury. Poor neuromuscular control of the trunk predicted knee injury risk in a prospective study of 277 college athletes.8 That study measured control, not size: a large core is not necessarily a well-coordinated one.

Muscle reserve. Core muscle area on CT has been associated with surgical outcomes,9 although using the psoas alone as a marker of global sarcopenia has been criticized.10

Reading the results

Charder reports the estimated area of each muscle group (cm²), the percentage versus a standard physique (100% is the reference), and a core score relating core development to whole-body skeletal muscle. The manufacturer associates scores below 70 with higher risk of sports injury or chronic pain and scores above 85 with good core capacity; these are manufacturer cut-offs, not clinical consensus.

  • Always compare patients with themselves, on the same device and under the same conditions.
  • Keep the model’s standard error in mind: small changes may fall within it.
  • Pair the estimate with functional tests of trunk stability and endurance.
  • With back pain, neurological deficit or suspected pathology, imaging and clinical evaluation remain the standard.

Availability

The MA601 reports total core area and score on its fitness result sheet, and the MA801 expands the report to the four muscle groups. Availability depends on software version and the result sheet configured.

See the core report in action

Ask us for sample MA601 and MA801 reports and the manufacturer’s validation documentation.

Request informationSee analyzers
References
  1. Shen W, et al. Total body skeletal muscle and adipose tissue volumes: estimation from a single abdominal cross-sectional image. J Appl Physiol, 2004.
  2. Tsai CC, Hsieh KC (Charder Electronic). Method of evaluating core muscles by bioimpedance technology. U.S. Patent 12,419,532 B2, 2025.
  3. Chu LP, et al. Preliminary study on the application of bioimpedance analysis to measure the psoas major muscle in older adults. PLOS ONE, 2023;18(3):e0275884.
  4. A potential bioelectrical impedance equation for estimating skeletal muscle area using computed tomography in colorectal cancer. Scientific Reports, 2025.
  5. Fortin M, Macedo LG. Multifidus and paraspinal muscle group cross-sectional areas of patients with low back pain and control patients. Physical Therapy, 2013.
  6. Ranger TA, et al. Are the size and composition of the paraspinal muscles associated with low back pain? The Spine Journal, 2017.
  7. Ranger TA, et al. Paraspinal muscle cross-sectional area predicts low back disability but not pain intensity. The Spine Journal, 2019.
  8. Zazulak BT, et al. Deficits in neuromuscular control of the trunk predict knee injury risk. Am J Sports Med, 2007.
  9. Englesbe MJ, et al. Analytic morphomics, core muscle size, and surgical outcomes. Annals of Surgery, 2012.
  10. Baracos VE. Psoas as a sentinel muscle for sarcopenia: a flawed premise. J Cachexia Sarcopenia Muscle, 2017.

Informational article for healthcare professionals. Core-model validation data come from the manufacturer’s patent documentation, whose inventors are affiliated with Charder; core-score cut-offs are the manufacturer’s own. Bioimpedance results are estimates and should be interpreted in clinical context.

Continue reading

All articles
For clinics & health systems

Bring objective measurement to your practice

Charder body composition analyzers, medical scales, stadiometers and dynamometers — FDA registered, free U.S. shipping and a 12-month warranty.

Join Waitlist We will inform you when the product arrives in stock. Please leave your valid email address below.